8 HP Double Condenser Portable Water Chiller Units Water Cooled Ac Unit 380V

Brand Name : EUROSTARS
Model Number : ESSA-08STS
Certification : CE
Place of Origin : GuangDong,China
MOQ : 1pc
Price : Negotiable
Payment Terms : T/T, L/C, Western Union
Supply Ability : 2000pcs/year
Delivery Time : 25 working days, peak season or nonstandard unit need 45~50 days
Packaging Details : Film or standard export wooden package
Panel material : Galvanized sheet
Chiller frame : strong
Condenser : V type
Evaporator : SS coil in SS tank
CNP pump : Horizontal
Voltage : 380V
Contact Now

8 HP Double Condenser Portable Water Chiller Units Water Cooled Ac Unit 380V


1. EUROSTARS Water Chiller Manufacturer Parameter Table


ItemParameter nameThe factory default valueSetting rangeNote
Control Setting* Push [Pump] to startOFFOFF/ON

OFF: press “compressor” button to start compressor;

ON: press “pump” button to start compressor automatically

Auto start when power recoveryOFFOFF/ON

ON: automatically start when power recovery;

OFF: not automatically start when power recovery;

Note: when “start way” is set “Remote”,this function no exist

Alarm output wayMute to keep outputMute to keep output/Mute stop output

Mute keep output: press “alarm output”once failure occurs;

Mute stop output: press “alarm output” when no failure occurs, after mute.

Alarm output typeNormally openNormally close/Normally open

Normally open: relay is switch on when failure occurs;

Normally close: relay is switch off when failure occurs;

* Low water level solutionStop the pumpStop the pump/ keep pump work

Stop the water pump: stop pump work when low water level occurs

Keep water pump work: keep pump work when low water level occurs

* Lack of water flow solutionStop the pumpStop the pump/ keep pump work

Stop the water pump: stop pump work when low water level occurs

Keep water pump work:

keep pump work when low water level occurs

*Current detectionYESYES/NO

YES: there is a current detection module;

NO: there is no current detection module.

* Rated current of compressor0.3A0~35.0A

0 A: Don't detect the fault current.

When[current detect] is set “OFF”, don't show this parameter

* Rated current of chilled pump0.3A0~35.0A
* Rated current of cooling pump0.3A0~35.0A
* Three-phase electrical testingYESYES/OFFYES: Check whether phase lack or phase reverse.
Antifreeze/cooling overloadCooling overloadCooling overload / antifreezeChoose switch DI1 input function
Temperature settingLoad deviation1.0℃0~10.0℃temperature deviation of compressor open
unload deviation1.0℃0~10.0℃temperature deviation of compressor close

Temp. Set

upper limit

30.0℃0~99.9℃Temperature setting ranges

Temp. Set

lower limit

5.0℃-38.0~99.9℃
Temperature compensation0.0℃-9.9~9.9℃Compensate for outlet water temperature
Low temp. protection4.0℃-40.0~99.9℃Low temp. protection.if water outlet temperature is less than the default value

Overtemperature

warning

50.0℃0~99.9℃Overtemperature warning when outlet water temperature is higher than the default value, chiller won't stop, can be reset automatically
Overtemperature alarm60.0℃0~99.9℃Overtemperature alarm when outlet water temperature is higher than the default value, chiller won't stop

Overtemperature

Return difference

5.0℃0~99.9℃The temperature difference after overtemperature fault reset,
Time settingChilled pump start delay10 seconds0~255 secondsChilled water pump start delay
Cooling pump delay10 seconds0~255 secondsCooling water pump start delay
Capacity control cycle5 seconds0~255 secondsCapacity control cycle
Compressor protection60 seconds0~255 secondsCompressor start delay repeatedly, interval time should be more than default value between compressor twice start
General failure debounce2 seconds0~255 secondsGeneral failure detect and debounce
Water flow lack debounce5 seconds0~255 secondsWater flow lack is valid when lasting time exceed default vaue
Low pressure detect dealy60 seconds0~255 secondsAllowed to low pressure input failure detect only after compressor run time exceed default value,
Low pressure debounce5 seconds0~255 secondsLow pressure failure debounce time
The compressor running time0 hours0~9999 hours

Zero:invalid

Non-zero: Chiller can’t start when compressor total run time exceed the default value

ON/OFF Switch Setting*compressor high pressureNormally openNormally close/Normally openChoice for ON/OFF
*compressor low pressureNormally closeNormally close/Normally open
*compressor overloadNormally openNormally close/Normally open
*water level switchNormally closeNormally close/Normally open
* water flow switchNormally closeNormally close/Normally open
* Chilled pump overloadNormally openNormally close/Normally open
* remote switchNormally closeNormally close/Normally open

Valid after start way choose “remote”;

Normally close: input swithch on start; Normally open: input switch off start .

* cooling pump overloadNormally openNormally close/Normally openChoice for ON/OFF

2. EUROSTARS Water Chiller Technical Datas:

Model ESSA-02STS(1)02STS(2)02STS03STS05STS(1)05STS08STS10STS
Rated Cooling CapacityKW2.765.729.3112.5415.8218.7325.0831.64
USRT0.781.632.653.574.505.337.139.00
×1000 kcal/h2.374.928.0110.7813.6116.1121.5727.21
Input Power (KW)(1)0.831.652.63.624.365.066.748.8
Input Power (KW)(2)1.22.023.154.174.915.617.849.9
Comp. Input Power×Qty. (KW)0.74*11.52*12.41*13.24*13.98*14.68*13.24*23.98*2
Throttle ModeCapillary Tube/Expansion Valve
Power Supply1φ-220-240V-50HZ3φ-380/400/415/440V-50HZ
Safety ProtectionPressure,Overload,Anti-freeze,Delay,Over-temperature,Water Flow Protection
RefrigerantR22
CondenserRipple Aluminum Fins around Cooper Pipe
FanTypeAxial Type
Power(KW)0.090.130.190.380.380.380.460.84
Air flow(CMH)150028004000650068007500930012000
EvaporatorTypePlate Type/Shell and Tube
Chilled liquid flow(m³/h)0.470.981.602.162.723.224.315.44
Water side Max pressure1Mpa
Dia. of water inlet/outletDN15DN20DN25DN25DN25DN25DN40DN40
Water pump
(optional)
Head(m)2020202020202020
Power(kw)0.370.370.550.550.550.551.11.1
Running Noise dB(A)5859606262626465
Total weight (Kg)75120150180180200230260

Model ESSA-12STS15DTS20DTS25DTS30TTS35TTS35TTS(1)35TTS(2)
Rated Cooling CapacityKW37.4649.3265.6074.0898.40131.20148.20185.20
USRT10.6514.0218.6521.0627.9837.3042.1452.66
×1000 kcal/h32.2242.4256.4263.7184.62112.83127.45159.27
Input Power (KW)(1)10.213.2417.8819.8626.8235.7640.2249.6
Input Power (KW)(2)11.315.4420.0822.0630.5739.5144.2255.1
Comp. Input Power×Qty. (KW)4.68*26.07*28.09*29.08*28.09*38.09*49.08*49.08*5
Throttle ModeExpansion Valve
Power Supply3φ-380/400/415/440V-50HZ
Safety ProtectionPressure,Overload,Anti-freeze,Delay,Over-temperature,Water Flow Protection
RefrigerantR22
CondenserRipple Aluminum Fins around Cooper Pipe
FanTypeAxial Type
Power(KW)0.841.11.71.72.553.43.94.2
Air flow(CMH)1300016000200002400029000400004800060000
EvaporatorTypePlate Type/Shell and Tube
Chilled liquid flow(m³/h)6.448.4811.2812.7416.9222.5725.4931.85
Water side Max pressure1Mpa
Dia. of water inlet/outletDN40DN50DN50DN50DN65DN80DN80DN80
Water pump
(optional)
Head(m)2020202020202020
Power(kw)1.12.22.22.23.753.754.05.5
Running Noise dB(A)6567686868686868
Total weight (Kg)35065075012001300150018002100

3. Product Line, Product Photo ,Loading Photo or Installation Photo


Product Tags:

water chiller units

      

water chilling unit

      
China Customized Inflatable Bumper Ball Game Bubble Adult Grass CE supplier

8 HP Double Condenser Portable Water Chiller Units Water Cooled Ac Unit 380V Images

Inquiry Cart 0
Send your message to this supplier
 
From:
Enter your email please.
To: Shenzhen Eurostars Technology Co., Ltd.
Subject:
Message:
Characters Remaining: (0/3000)
 
Inquiry Cart 0