25KW Geothermal Water Source Heat Pump HVAC Most Efficient Heat Pump

Brand Name : Eurostars
Model Number : ESSW20GCH
Certification : CE
Place of Origin : Shenzhen, Guangdong, China.
MOQ : 1 piece
Price : Negotiable
Payment Terms : T/T, L/C, Western Union
Supply Ability : 8000 pcs per year
Delivery Time : 25 days after deposit confirmed
Packaging Details : Wooden crate package
Refrigerant Type : R407C
Refrigerant Charge : 3.3Kg
Compressor Brand : Copeland
Compressor Qty : 1
Casing : Spray Coating
Power Supply : 380V/3PH/50HZ
Contact Now

25KW Geothermal Water Source Heat Pump HVAC Most Efficient Heat Pump


1. Geothermal source heat pump types

There are four basic types of ground loop systems. Three of these: horizontal, vertical, and pond/lake, are closed-loop systems. The fourth type of system is the open-loop option.

Which one of these is best depends on the climate, soil conditions, available land, and local installation costs at the site. All of these approaches can be used for residential and commercial building applications.


(1) Closed-Loop Systems

Most closed-loop geothermal heat pumps circulate an antifreeze solution through a closed loop, usually made of plastic tubing, that is buried in the ground or submerged in water. A heat exchanger transfers heat between the refrigerant in the heat pump and the antifreeze solution in the closed loop. The loop can be in a horizontal, vertical, or pond/lake configuration.

One variant of this approach, called direct exchange, does not use a heat exchanger and instead pumps the refrigerant through copper tubing that is buried in the ground in a horizontal or vertical configuration. Direct exchange systems require a larger compressor and work best in moist soils (sometimes requiring additional irrigation to keep the soil moist), but you should avoid installing in soils corrosive to the copper tubing. Because these systems circulate refrigerant through the ground, local environmental regulations may prohibit their use in some locations.


(2) Open-Loop System

This type of system uses well or surface body water as the heat exchange fluid that circulates directly through the GSHP system. Once it has circulated through the system, the water returns to the ground through the well, a recharge well, or surface discharge. This option is obviously practical only where there is an adequate supply of relatively clean water, and all local codes and regulations regarding groundwater discharge are met.


2. Geothermal water source heat pump main components

(1) Scroll compressor

(2) Double pipe load side heat exchanger

(3) Plate type source side heat exchanger

(4) Digital controller

(5) 4 way reversible valve

(6) Thermal expansion valve

(7) Low high pressure switch

(8) Contactor and thermal relay


3. Geothermal source heat pump technical specifications

ModelESSW10GCHESSW15GCHESSW20GCHESSW25GCHESSW40GCH
Technical Parameter
Heating input powerHeating modeKW2.12.354.154.98.35
Heating capacityKW10.511.821.325.242.6
COP5.005.025.135.145.10
Cooling input powerCooling modeKW1.51.733.46
Cooling capacityKW6.87.81416.528
EER4.534.594.674.854.67
Pipe sizemm2525252532
Unit noisedb5050505050
N.W.kg9090123133286
G.W.kg9494133143301
Level of protectionIPX4IPX4IPX4IPX4IPX4
Electric shock proof gradeIIIII
Unit Standard Components
Unit cabinetGalvanized sheet/ Spray coating / gray color
Unit dimensionmm710*520*1000710*520*1000710*520*1000710*520*10001280*830*800
Packing dimensionmm760*570*1130760*570*1130760*570*1130760*570*11301330*880*930
RefrigerantR407C/2.4kg*1R407C/2.4kg*1R407C/3.3kg*1R407C/3.6kg*1R407C/3.3kg*2
Power supply220V~240V/50Hz380V~415V/50Hz/3ph
Unit compressorCopeland.
load side heat exchangerDouble-pipe
Source side heat exchangerPlate Type
4-way valveSANHUA
Thermal expansion valveEmerson
AC contactor and thermal relayFuji
ControllerEurostars multiple function controller
Protection functionTemperature protection, time protection, water flow protection, antifreeze protection, current protection
Water pressure switch0.015Mpa :OFF, 0.03Mpa: ON
High pressure switch3.0/3.4MPa
Low pressure switch0.15/0.32MPa
Working modeHeating mode and cooling mode

4. Geothermal source heat pump installation instruction



Product Tags:

water source heat pump

      

water to water heat pump

      
China Customized Inflatable Bumper Ball Game Bubble Adult Grass CE supplier

25KW Geothermal Water Source Heat Pump HVAC Most Efficient Heat Pump Images

Inquiry Cart 0
Send your message to this supplier
 
From:
Enter your email please.
To: Shenzhen Eurostars Technology Co., Ltd.
Subject:
Message:
Characters Remaining: (0/3000)
 
Inquiry Cart 0